Add to Cart
KRD13 series high energy shock test system is specially designed to meet the requirements of military industry and home appliances. The system adopts the principle of pneumatic energy storage expansion. By adjusting the inflation pressure, various high-level acceleration tests can be easily implemented in a short stroke.
For the classic drop test, it’s equipped with the corresponding shock amplifier to complete drop test.
1. Windows-based stable control system, full-automatic remote-control interface
2. Pneumatic cylinder driving with advantages of large driving force, short accelerating stroke, low cost and pollution free.
3. Automatic control of lifting height with high accuracy and good repeatability
4. Adopts the high strength and hardness cast aluminum table, which has high first-order resonance frequency, featured with low noise and no clutter
5. The most reliable double-brake system: effectively avoids secondary rebound collisions, more securely positioning the table, and more reliably guarantees the safety of the operator.
6. Easy installation: the device comes with a base, due to short driving stroke of the pneumatic cylinder, the footprint is small.
Technical Specifications
Model Parameters |
KRD13-50 |
KRD13-100 |
KRD13-200 |
KRD13-500 |
KRD13-800 |
KRD13-1000 |
KRD13-2000 |
|
Rated Load (kg) |
50 |
100 |
200 |
500 |
800 |
1000 |
2000 |
|
Table Size (mm) |
500×500 |
600×600 |
800×800 |
1000×1000 |
1200×1200 |
1500×1500 |
2000×2000 |
|
Peak Acc. (G) |
Half-Sine |
10~1500 |
10-1000 |
10-500 |
10-400 |
10-300 |
10-200 |
|
Post-Peak Sawtooth |
10~200 |
10~100 |
10-50 |
|||||
Trapezoid |
15-200 |
15-200 |
15-100 |
15-100 |
15-60 |
15-50 |
30-50 |
|
Pulse Duration (ms) |
Half-Sine |
2~60 |
2~60 |
3~60 |
4~60 |
5~60 |
6~60 |
8~60 |
Post-Peak Sawtooth |
3~18 |
6~18 |
||||||
Trapezoid |
3~18 |
6~18 |
||||||
Bump Waveform |
Half Sine Waveform |
|||||||
Shock Peak Acceleration (g) |
5~100 |
|||||||
Shock Pulse Duration(ms) |
3~30 |
|||||||
Bump Rate (Times/Min) |
10-120 |
|||||||
Overall Dimension (mm) |
1200×1200×1500 |
1200×1200×1500 |
1200×1200×1500 |
1300×1300×1600 |
1500×1500×1700 |
1600×1600×1800 |
2000×2000×1900 |
|
Weight (kg) |
3000 |
3200 |
3400 |
4000 |
5000 |
6000 |
8000 |
|
Condition |
Environment |
Temperature range 0 ~ 40℃; Humidity ≤ 80%, non-condense |
||||||
Power |
AC220V±10%, 50Hz |
|||||||
Air source |
≤1MPa |
|||||||
Floor |
Foundation-free,
the cement floor shall be leveled and the working distance of 800 ~ 1000mm
shall be reserved around the equipment |
|||||||
Standards |
IEC68-2-27 MIL-STD-202 MIL-STD-750 MIL-STD-810 MIL-STD-883 UN38.3 IEC62281 IEC62133-2 UL2054 IEEE1625 SAEJ2929 IEC62660-2 ISO12405-3 UL2580 |